You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
FANUC DCS Safety System — Configuration and Stop Modes
domain
fanuc
subdomain
safety
tags
dcs
safety
dual-check
emergency-stop
fence
stop-mode
safety-io
iso13849
status
published
source
internal-training
confidence
0.95
created
2026-07-14
Problem
FANUC DCS (Dual Check Safety) is a critical safety system that uses independent dual CPUs to monitor robot position and speed. Misconfiguration can lead to safety violations or false trips. Engineers need to understand the DCS architecture, stop modes, and safety I/O to configure it correctly.
Solution
DCS Overview
Independent dual-CPU monitoring of motor speed and position
Dual-circuit power cutoff on detection of speed/position anomalies
Meets ISO 13849-1 and IEC 61508 requirements
Default emergency stop password: 1111
DCS Function Table
Function
Category
PL/SIL
Description
Emergency Stop
Cat 4
PL e / SIL 3
Cut drive power on E-stop button (default)
Position/Speed Check
Option
Cat 3 / PL d / SIL 2
Monitor position and speed, cut on exceed
Joint Speed Check
Option
Cat 3 / PL d / SIL 2
Monitor joint speed, cut on exceed
Basic Position Check
Option
Cat 3 / PL d / SIL 2
Monitor Cartesian position, cut on exceed
Safety I/O Connection
Option
Cat 4 / PL e / SIL 3
Operate safety signals
External Mode Switch
Option
Cat 4 / PL e / SIL 3
Replace panel mode switch
Device Network Security
Option
Cat 4 / PL e / SIL 3
Network security slave device
Safety PMC
Option
Cat 4 / PL e / SIL 3
Safety I/O sequence via ladder
Additional Axis Servo Off
Option
Cat 4 / PL e / SIL 3
Cut additional axis motor power
Safety I/O Consistency
Default
Cat 4 / PL e / SIL 3
Cut power on I/O group inconsistency
Stop Types
Type
Description
P-Stop (Power Stop)
Cut servo power instantly — robot stops immediately
C-Stop (Control Stop)
Decelerate then cut servo power — controlled stop
Hold
Maintain servo power, decelerate to stop — softest stop
Stop Modes
Mode
E-Stop Button
External E-Stop
Fence Open
SVOFF Input
A
P-Stop
P-Stop
C-Stop
C-Stop
B
P-Stop
P-Stop
P-Stop
P-Stop
C
C-Stop
C-Stop
C-Stop
C-Stop
Safety I/O Signals
Signal
Description
EES1 / EES2
External emergency stop input (dual circuit)
EAS1 / EAS2
Fence input (dual circuit)
FENCE1 / FENCE2
Fence signal (single circuit)
EMGIN1 / EMGIN2
External emergency stop (single circuit)
SSO[3] / SSO[4]
DCS safety I/O
DCS Parameter Management
DCS parameters are stored in separate memory from regular parameters:
DCSPOS.SV — Position check parameters
DCSIOC.SV — I/O check parameters
SYSCIPS.SV — System safety parameters
To change DCS parameters:
Change setting parameters first
Apply to DCS parameters
Enter 4-digit password (default: 1111)
Stop Distance Calculation
Stop Distance = (Motion Speed × Scan Time) + Coast Distance at Power Cutoff
Standard scan time: 8ms
Safety signal latency: 2ms (DCS I/O), 4ms (PROFINET)
Common DCS Alarms
SYST-212: DCS parameters need application
SYST-218: DCS function not available for this model